Charts for CSV1000, Contrast Sensitivity
CSV 1000 HOTV Chart
The CSV- 1000HOTV test face provides a LogMAR test in which only four letters are used; H, O, T and V. This test is very useful for evaluating children or patients which commonly reverse the appearance of objects. These letters were chosen because all are symmetric along the vertical axis. A prompt card is provided.
SKU: CSV-1000HOTV -
-
-
-
Contrast Sensitivity, Distance Charts, Ophthalmic Clinical Research, Pelli Robson chart
Pelli Robson Contrast Sensitivity Chart Set of 2
Contrast Sensitivity, Distance Charts, Ophthalmic Clinical Research, Pelli Robson chartPelli Robson Contrast Sensitivity Chart Set of 2
Features Traditional Sloan Optotypes. For use at 100 cm (1m). Includes two charts which may be wall or easel mounted and score sheets.
Acuity Level 40M (20/320) at 1 Meter.
SKU: 5014 -
-
-
-
Charts for CSV1000, Contrast Sensitivity
CSV 1000LH Symbol Chart
The CSV-1000LH Symbol test face provides common symbols for the evaluation of illiterate or non-English speaking patients. The test is also widely used for the evaluation of children. The CSV-1000LH is in the ETDRS format. A patient prompt card is included.
SKU: CSV-1000LH Symbol -
Charts for CSV1000, Contrast Sensitivity
CSV 1000SLanC Chart
The CSV-l000SLanC test face provides the same tests as the standard CSV-1000S, except that the acuity test is presented in Landolt C format.
This test is very useful when testing patients who cannot read the English alphabet.
SKU: CSV-1000SLanC -
Charts for CSV1000, Contrast Sensitivity
CSV 1000 1.5CPD Chart
The CSV-1000-1.5CPD is a special test face designed specifically for Food and Drug Administration clinical trials which require the testing of contrast sensitivity at 1.5 cycles/degree under mesopic lighting conditions
SKU: CSV-1000-1.5CPD -
-
Charts for CSV1000, Contrast Sensitivity
CSV 1000S Chart
The CSV-1000S test face is widely used for in or out-of-office screenings and for cataract evaluation. This test presents standard visual acuity from 20/15 to 20/200, two rows of spatial frequencies (6 and 12 cycles/degree) and a real-world driver’s scene.
SKU: CSV-1000S -
Accessories CSV 1000 & 2000, Contrast Sensitivity
The floor stand for CSV-1000 & CSV-2000
The CSV-1000 can hang on the wavewall, sit on a table or hang from a rolling floor stand. The device can also be used in conjunction with neutral density lenses or trial frames which provide the ability to test mesopic contrast sensitivity, acuity and contrast sensitivity with glare. See the images below for these accessories
SKU: The Floor Stand -
Charts for CSV1000, Contrast Sensitivity
CSV 1000E Chart
The CSV-1000E contrast sensitivity chart test face is the most widely used contrast sensitivity test in the world. This test provides for four (4) rows of sine-wave gratings. At the recommended test distance of 8 ft (2.5 meters), these gratings test the spatial frequencies of 3, 6, 12 and 18 cycles/degree (CPD).
SKU: CSV-1000E -
Accessories CSV 1000 & 2000, Contrast Sensitivity
Mesopic Lenses in Wire Frames
The CSV-1000 can hang on the wavewall, sit on a table or hang from a rolling floor stand. The device can also be used in conjunction with neutral density lenses or trial frames which provide the ability to test mesopic contrast sensitivity, acuity and contrast sensitivity with glare. See the images below for these accessories.
SKU: Mesopic Lenses in Wire Frames -
Accessories CSV 1000 & 2000, Contrast Sensitivity
Mesopic Lenses in Trial Lenses
The CSV-1000 can hang on the wavewall, sit on a table or hang from a rolling floor stand. The device can also be used in conjunction with neutral density lenses or trial frames which provide the ability to test mesopic contrast sensitivity, acuity and contrast sensitivity with glare. See the images below for these accessories
SKU: Mesopic Lenses in Trial Lenses -
Contrast Sensitivity, CSV-1000HGT
CSV 1000HGT Standardized Glare Test
Since 1991, the CSV-1000 has been a mainstay for clinical trials that measure contrast sensitivity, ETDRS acuity, low contrast acuity and glare sensitivity. The self-standardized back lit system automatically initiates and maintains a light level of 85 cd/m2. This light level is recommended by the FDA for vision evaluation. The system is also easy to use and requires no maintenance, thus greatly reducing overhead in clinical trials. The cool fluorescent bulbs used in the CSV-1000 have a 20,000 hour life and draw very little energy. Using the CSV-1000 makes bulb replacement obsolete and creates an energy saving footprint. The device is also configured electrically with a universal power supply so that is very simple to adapt for local electrical requirements by using a plug cord for the country of choice.
SKU: CSV1000HG -
Contrast Sensitivity, CSV2000
CSV 2000
With the CSV-2000, you have the power to test for more than just acuity and contrast sensitivity
AcQviz measures the monitor light level and adjusts the level to 85 cd/m2.
The CSV-2000 is the only clinical digital vision testing device that automatically calibrates the monitor lighting so that all testing is conducted at the same light level. This standardization ensures consistent vision test results from room-to-room and from practice-to-practice. Auto-calibration is accomplished through patented technology from Guardion Health Sciences (Parent Company of VectorVision), called AcQviz.
SKU: CSV-2000 -
Contrast Sensitivity, CSV1000
CSV 1000
The CSV-1000 instrument is the recognized world-wide leader for standardized contrast sensitivity, ETDRS and glare testing. The patented auto-calibration circuitry provides for standard and consistent test conditions without a hassle. The instrument automatically controls the test lighting to a level of 85 cd/m2, which is the light level recommended for vision testing by the National Academy of Sciences and adopted by the FDA as the required testing light level for clinical trials. Ease of use is one reason why the CSV-1000 is used in eye clinics in more than 60 countries. All you have to do is turn on the device and it is ready to evaluate patients using standardized and highly accurate tests.
SKU: CSV-1000 -
Contrast Sensitivity, CSV1000
CSV 1000 Accessories
The CSV-1000 can hang on the wavewall, sit on a table or hang from a rolling floor stand. The device can also be used in conjunction with neutral density lenses or trial frames which provide the ability to test mesopic contrast sensitivity, acuity and contrast sensitivity with glare. See the images below for these accessories
SKU: CSV-1000 Accessories -
Contrast Sensitivity, CSV1000
CSV 1000 Low Contrast Acuity Tests
A variety of low contrast acuity tests can be used with the CSV-1000 or CSV-1000HGT. These tests are used primarily for screening, cataract documentation or in clinical trials. Please see the pictures and images below to learn more about the various low contrast acuity tests available from VectorVision. Other contrast levels and test types are available upon request.
SKU: CSV-1000 Low Contrast -
Contrast Sensitivity, CSV1000
CSV 1000 Standardized Contrast Sensitivity Tests
Contrast sensitivity testing is accomplished worldwide by eye doctors in more than 60 countries using the CSV-1000 instrument. The ease of use, standardization and accuracy make it a mainstay for measuring the functional vision for cataract patients, evaluating refractive surgery and IOLs and for assessing disease progressing and treatment. Please review the images and text below to learn about the various contrast sensitivity test faces that can be used with the CSV-1000. (Please visit this page for background information describing the basics of contrast sensitivity.
SKU: CSV-1000 Contrast Test